The Rosemount 3051S series of instrumentation offers scalable solutions for pressure, flow, and level measurements, improving operations in various areas, such as production, safety, and energy efficiency. This advanced series utilizes innovative technology and manufacturing for high-performance results.
Overview of the Rosemount 3051S
The Rosemount 3051S stands out as a highly advanced pressure, flow, and level measurement solution, designed with a focus on reliability and accuracy. It incorporates the patented Coplanar technology, making it a unique offering in the market. The SuperModule platform of the 3051S boasts an all-welded hermetic SST design, ensuring top-tier field reliability. Its ultra-performance provides exceptional accuracy, with up to 0.025% and a 200⁚1 rangedown, while the ultra-for-flow variant offers up to 0.04% of reading and 14⁚1 flow turndown. This series also features 15-year stability and a limited warranty of the same duration, along with SIL3 capability. The 3051S also provides options for both wired and wireless configurations, demonstrating its versatility and adaptability to various industrial environments. The device is designed to optimize operations across critical areas, from initial startup to final shutdown, with the support of service technicians.
Key Features and Benefits
The Rosemount 3051S series offers scalable measurement solutions, providing flexibility for various applications. Its advanced diagnostics enhance reliability, optimizing performance and reducing downtime, making it a highly beneficial choice for industrial use.
Scalable Measurement Solutions
The Rosemount 3051S series provides versatile and scalable measurement solutions, accommodating a wide range of industrial applications and requirements. These solutions are designed to improve operational efficiency across pressure, flow, and level measurements. The series allows for configuration to suit specific needs, ensuring accurate and reliable data. With its advanced technology, the 3051S delivers superior performance and flexibility, adapting to changing demands within a plant or facility. Its design enables easy integration into existing systems, reducing complexity and potential disruptions. The scalable nature of this series also allows for future expansion and modifications, making it a sustainable investment for industrial operations. This scalability is a key benefit, ensuring that measurement needs are met effectively and efficiently, while maintaining high standards of accuracy and reliability.
Advanced Diagnostics and Reliability
The Rosemount 3051S series is engineered with advanced diagnostics to enhance reliability and minimize downtime, contributing to improved plant safety and performance. The series features a robust design, utilizing an all-welded hermetic SST construction to provide industry-leading field reliability. Its advanced diagnostic capabilities allow for proactive monitoring and identification of potential issues, enabling timely maintenance and preventing costly breakdowns. With 15-year stability and a 15-year limited warranty, the 3051S series offers long-term, dependable operation. Moreover, it is SIL3 capable, meeting rigorous safety standards. These diagnostic features provide the process insight necessary to optimize every point in the operation, ensuring consistent and trustworthy results. The high reliability of the 3051S series results in reduced maintenance costs and maximized operational uptime.
Technical Specifications
The Rosemount 3051S series offers detailed technical specifications, including performance metrics, material options, and configuration choices. These specifications ensure the instrument meets various application requirements with precision and reliability.
Performance Specifications
The Rosemount 3051S series boasts exceptional performance specifications, ensuring accurate and reliable measurements across various applications. These specifications are defined under reference conditions, using silicone oil fill, glass-filled PTFE o-rings, and stainless steel materials. The transmitters, whether utilizing a Coplanar flange or 1/2 in.- 14 NPT process connections, have digital trim values set to match the range points. Conformance to specification is guaranteed to at least 3σ, demonstrating the high level of precision achieved. The ultra-performance variant of the 3051S offers up to 0.025% accuracy with a 200⁚1 rangedown, while the ultra for flow performance provides up to 0.04% of reading accuracy and a 14⁚1 flow turndown. The series includes a 15-year stability guarantee and limited warranty, further emphasizing its long-term reliability. These detailed specifications ensure users can confidently rely on the Rosemount 3051S for critical measurements.
Material and Configuration Options
The Rosemount 3051S series offers a range of material and configuration options to suit diverse application needs. The all-welded hermetic stainless steel design ensures the highest field reliability. Material selection is a critical factor, and purchasers are responsible for selecting the appropriate materials for their specific needs, which includes both the body and wetted parts. Available process connections include Coplanar flanges (3051S_C) and 1/2 in.- 14 NPT (3051S_T) options. Furthermore, the Rosemount 3051S features a variety of flange process connection sizes and adapter options, such as 1/8 NPT connections and 1/4 NPT adapters, to meet different installation requirements. These options guarantee that the transmitter can be configured to fit multiple process conditions and environments while maintaining performance standards. The variety of materials and configurations ensures that a system can be built to fit many applications.
Installation and Operation
A quick installation guide is provided with each transmitter, detailing basic installation and startup procedures. Dimensional drawings for various configurations are also included for reference.
Quick Installation Guide
Every Rosemount 3051S transmitter is shipped with a comprehensive Quick Installation Guide, identified by document number 00825-0100-4802. This guide is designed to provide users with clear and concise instructions for basic installation and initial startup procedures. The guide ensures that users can swiftly and accurately set up their pressure transmitters, minimizing downtime and maximizing efficiency. It covers essential steps such as mounting the transmitter securely, connecting process piping correctly, and powering the device appropriately. This document serves as a critical resource for both new and experienced users, helping to avoid common errors during the installation phase. By following the steps outlined in the Quick Installation Guide, users can achieve optimal performance from their Rosemount 3051S transmitters. The guide also references other relevant documentation for more in-depth information.
Wireless Capabilities and Options
The Rosemount 3051S series offers advanced wireless capabilities, providing flexible deployment options and reducing the costs associated with traditional wired installations. These wireless transmitters allow for remote monitoring and data transmission, enhancing accessibility and control over process variables. The wireless update rate is user-selectable, ranging from 1 second to 60 minutes, providing adjustable power consumption based on application needs. A power module, which is field-replaceable, ensures a long operational life of up to 10 years, reducing maintenance requirements. The transmitter also features flange process connections with 1/8 NPT size, with flange adapters available for 1/4 NPT connections. This adaptability makes the Rosemount 3051S suitable for diverse industrial environments. Dimensional drawings for wireless variations and mounting configurations are available, allowing users to optimize installation.
Applications and Industries
The Rosemount 3051S series optimizes operations across various industries by providing accurate measurements for production, quality, energy efficiency, and safety, leveraging scalable solutions for diverse applications.
Optimizing Operations with 3051S
The Rosemount 3051S series significantly enhances operational efficiency across various industries by providing highly accurate and reliable pressure, flow, and level measurements. This advanced instrumentation enables businesses to optimize key areas such as production, product quality, energy consumption, and overall safety protocols. By leveraging the scalable nature of the 3051S, companies can tailor measurement solutions to their specific needs, ensuring optimal performance and minimizing operational risks. The series’ advanced diagnostics capabilities further contribute to proactive maintenance, reducing downtime and enhancing the long-term reliability of plant operations. With the 3051S, organizations gain crucial insights into their processes, enabling them to make data-driven decisions and achieve superior operational outcomes across the board. Its versatility and robust design make it a valuable asset for any industrial setting seeking to improve efficiency and safety.
Additional Resources
For detailed information, refer to the Quick Installation Guide (document number 00825-0100-4802) and the product data sheet for the Rosemount 3051S series. Manual 00809-0100-4801 is available for HART configurations.
Related Manuals and Documentation
To ensure proper installation and operation of your Rosemount 3051S series transmitter, several key documents are available. A Quick Installation Guide, document number 00825-0100-4802, is shipped with each transmitter, outlining the basic procedures for setup and startup. This guide includes dimensional drawings for various 3051S wireless configurations and mounting options, found in Appendix A. For users working with HART protocol, the dedicated manual, 00809-0100-4801, provides specific instructions for configuring, troubleshooting, operating, and maintaining the transmitters. Additional information regarding product options can be found in the Rosemount 3051S Series of Instrumentation Product Data Sheet. These resources offer detailed specifications, material selection guidelines, and other critical information needed for successful implementation and maintenance of the Rosemount 3051S. The product data sheet number is 00813-0100-4001, Rev HA March 2008 and provides important information about product options and specifications.